RIA Analysis of Unprotected TRIGA Reactor

M.H. Altaf, S.M. Tazul Islam, N.H. Badrun

Abstract


An RIA (reactivity initiated accident) analysis has been carried out for the TRIGA Mark II research reactor considering both step and ramp reactivity ranges within 0.5 % dk/k (< $1) to 2.0 % dk/k (>$2). The insertion time was set at 10 s. Based on the fact that a reactor becomes unprotected if scram does not work at the event of danger, to define unprotected conditions, the time to actuate scram (trip) was taken as close to total simulation time. In this long duration of scram inactivity, it is obtained from the present analysis that the reactor remained safe to up to 1.8 % dk/k ($2.57) for step reactivity and 1.99 % dk/k ($2.84) for ramp reactivity. In addition to negative temperature coefficient of reativity, probably the longer time of reactivity insertion keeps TRIGA safe even at larger magnitudes of reactivity during unprotected reactor transients. Coupled point kinetics, neutronics, and thermal hydraulics code EUREKA-2/R has been utilized for this work. It appears that EUREKA-2/RR predicts the sequence of unprotected transient scenario of TRIGA core with good approximation and the results will definitely be helpful for the reactor operators.


Keywords


Unprotected RIA; TRIGA; Doppler feedback; Cladding temperature

Full Text:

PDF


DOI: https://doi.org/10.17146/aij.2017.568



Copyright (c) 2017 Atom Indonesia

Creative Commons License